RIKA RK900-12

RK900-12

RIKA RK900-12

A weather instrument measuring wind speed and direction, air temperature, relative humidity, air pressure, solar irradiance, rainfall, PM1/PM2.5/PM10, illuminance, noise, visibility and UV. This configuration includes RS232 output and a 10 m cable.

Measurement parameters and specifications

The table covers only the sensors included in this configuration supplied by Kordil. Performance figures follow the technical sheet for this model.

ParameterPrincipleRangeResolutionAccuracy
Wind speedUltrasonic0–70 m/s0.1 m/s±3% FS
Wind directionUltrasonic0–359°1°±3°
Air temperatureMEMS−40 to +80 °C0.1 °C±0.5 °C
Relative humidityMEMS0–100% RH1% RH±3% RH
Air pressureMEMS300–1100 hPa0.1 hPa±1 hPa
Rainfall intensityRadar0–200 mm/h0.1 mm±5%
Solar irradianceSilicon cell0–2000 W/m²0.1 W/m²±5%
UV irradianceSilicon cell0–2000 W/m²0.1 W/m²±10%
IlluminanceSilicon cell0–200000 lx0.1 lx±5%
PM1 concentration————
PM2.5 concentrationPhotoelectric scattering0–2000 µg/m³1 µg/m³±5%
PM10 concentrationPhotoelectric scattering0–2000 µg/m³1 µg/m³±8%
VisibilityForward scattering10–10000 m1 m±15%
Noise levelMEMS30–130 dB0.1 dB±3 dB

FS = full scale; RH = relative humidity. —: Not specified in the technical sheet for this model.
The rainfall range describes intensity (mm/h); the 0.1 mm resolution refers to rainfall amount. PM1 is included in this configuration, but the technical sheet does not provide a separate PM1 range, resolution or accuracy.
The sensor measurement range differs from the instrument operating-temperature range; observe the operating conditions listed below.

Source: RK900-12 technical sheet (V5.3, 2026-04-16).

Electrical specifications and operating conditions

  • Wind speed range: 0–70 m/s
  • Supply: 12–24 VDC
  • Ingress protection: IP65
  • Power consumption: <1.7 W
  • Operating temperature: -20 … +70 °C

Technical specification · User manual

Connection and installation

The supplied instrument has RS232 output, a 12–24 VDC supply and a 10 m cable. Check the communication protocol and wiring against the product manual when integrating with your data acquisition system.

Contact Kordil for integration and a quotation

Technical sources: manufacturer-supplied RK900 series specifications and manuals. Features depend on the selected configuration.